COLA treats procedure approval as a director duty that cannot be handed off. Getting it right avoids one of the most common findings after a director change.

Reviewed November 27, 2026 by the Sound Lab Consultants laboratory compliance team

Short answer

COLA's guidance says procedures and changes must be approved and dated by the laboratory director before they are implemented, that this cannot be delegated, and that a new director should review and approve all procedures as soon as possible. CLIA requires an approved procedure manual available to all testing staff (42 CFR 493.1407(e)(13)).

Set up a clean approval system

  1. Index every procedure with version, effective date and review date.
  2. Director signs and dates each procedure and change before use.
  3. Keep retired versions for the required retention period.
  4. When the director changes, the new director reviews and signs every procedure.
  5. Use manufacturer inserts only where the director has reviewed and approved them as part of the procedure.

What a procedure should include

  • Specimen requirements and rejection criteria
  • Step-by-step test performance
  • Calibration and QC
  • Reportable and reference ranges
  • Critical values and notification
  • How results are derived
  • Limitations and interferences

COLA is a registered trademark of COLA, Inc. This site is not affiliated with or endorsed by COLA, CMS or CDC. COLA criteria are summarized in our own words; use the current COLA Accreditation Manual for exact criteria.

Regulations behind this page

Every requirement on this page comes from the CLIA regulations, Title 42 Code of Federal Regulations Part 493. Open any section for the official text.

RegulationWhat it covers
42 CFR § 493.1407Standard; Laboratory director responsibilitiesModerate complexity laboratory director responsibilities
Full text: 42 CFR § 493.1407 Standard; Laboratory director responsibilities

§ 493.1407 Standard; Laboratory director responsibilities. The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical consultant, clinical consultant, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications of §§ 493.1409, 493.1415, and 493.1421, respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. (c) The laboratory director must: (1) Be onsite at least once every 6 months, with at least 4 months between the minimum two on-site visits. Laboratory directors may elect to be on-site more frequently and must continue to be accessible to the laboratory to provide telephone or electronic consultation as needed; and (2) Provide documentation of these visits, including evidence of performing activities that are part of the laboratory director responsibilities. (d) Each individual may direct no more than five laboratories. (e) The laboratory director must— (1) Ensure that testing systems developed and used for each of the tests performed in the laboratory provide quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic, and postanalytic phases of testing; (2) Ensure that the physical plant and environmental conditions of the laboratory are appropriate for the testing performed and provide a safe environment in which employees are protected from physical, chemical, and biological hazards; (3) Ensure that— (i) The test methodologies selected have the capability of providing the quality of results required for patient care; (ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; and (iii) Laboratory personnel are performing the test methods as required for accurate and reliable results; (4) Ensure that the laboratory is enrolled in an HHS approved proficiency testing program for the testing performed and that— (i) The proficiency testing samples are tested as required under subpart H of this part; (ii) The results are returned within the timeframes established by the proficiency testing program; (iii) All proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require corrective action; and (iv) An approved corrective action plan is followed when any proficiency testing results are found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; (6) Ensure the establishment and maintenance of acceptable levels of analytical performance for each test system; (7) Ensure that all necessary remedial actions are taken and documented whenever significant deviations from the laboratory's established performance specifications are identified, and that patient test results are reported only when the system is functioning properly; (8) Ensure that reports of test results include pertinent information required for interpretation; (9) Ensure that consultation is available to the laboratory's clients on matters relating to the quality of the test results reported and their interpretation concerning specific patient conditions; (10) Employ a sufficient number of laboratory personnel with the appropriate education and either experience or training to provide appropriate consultation, properly supervise and accurately perform tests and report test results in accordance with the personnel responsibilities described in this subpart; (11) Ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results; (12) Ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills; (13) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; and (14) Specify, in writing, the responsibilities and duties of each consultant and each person, engaged in the performance of the preanalytic, analytic, and postanalytic phases of testing, that identifies which examinations and procedures each individual is authorized to perform, whether supervision is required for specimen processing, test performance or results reporting, and whether consultant or director review is required prior to reporting patient test results. [57 FR 7172, Feb. 28, 1992, as amended at 68 FR 3713, Jan. 24, 2003; 88 FR 90039, Dec. 28, 2023]

Source: eCFR, Title 42, Part 493, current as of November 24, 2026.

FAQ

Common questions

Can a technical consultant approve procedures?

COLA's guidance treats approval as a director duty that cannot be delegated.

Are electronic signatures OK?

Generally yes, if the system controls access and dates the approval.

Can we use the package insert as our procedure?

Only if the director has reviewed and approved it as part of the procedure.

Get a laboratory director

Tell us about your lab

Send the form and a Sound Lab Consultants team member replies within one business day with director options for your state, test menu and complexity.

Request a lab director

No obligation. Your details go only to Sound Lab Consultants.

Prefer to talk now? Call (602) 874-1311.

✓

Thank you. We have your request.

A Sound Lab Consultants team member will reply within one business day. To skip the wait, book a call now

Need a qualified laboratory director?